EVOLVE Electrical Customer Ideas

Our products depend on your feedback. No idea is too small or too big, we want to know where to make improvements and what features mean the most to our end users. Our customers drive our road map, thanks for sharing!

Place Connectors Button

Automatically size and place connectors on selected end of conduit run. I see this being a huge time saver when we have multiple conduits entering / exiting a ...
Suggested by: Brian Cass (20 Jul, '21) Upvoted: 22 Feb Comments: 4
Planned (Added to Roadmap) Feature Enhancement

Run Schedule Remember Path per Project

Currently when importing a run schedule the folder path is set to the last path used to import a feeder schedule. For users that work on multiple projects this ...
Suggested by: Jason (08 Jun, '22) Upvoted: 22 Apr Comments: 1
Needs more information or votes Feature Enhancement

Modifying Packages - Nested Elements

When modifying a package, if you remove an element that has nested components, those components are not removed from the package and needs to be selected manually. ...
Suggested by: O.Manningham (06 Jun, '22) Upvoted: 22 Apr Comments: 0
Needs more information or votes Feature Enhancement Prefab

ConduitRun_start auto-populate with connected equipment

Would like the conduitRun_Start and finish to autopopulate with connected equipment data.
Suggested by: Alain Lemieux (15 Jul, '21) Upvoted: 22 Apr Comments: 0
Needs more information or votes Feature Enhancement

Cable Tray Physical Size

Cable tray physical size is needed for coordination. Currently the tray is exact size to the trade size name. Basket Tray min, 1" sides and bottom. Ladder Tray min, ...
Suggested by: Anonymous (24 Jan, '20) Upvoted: 03 May, '23 Comments: 0
Needs more information or votes Content Feature Enhancement

Renumber Parallel Feeders in 1 Action

Using the renumber tool, I am renumbering each stick of conduit with a unique ID. When renumbering parallel feeders, it would save a lot of time if we can renumber ...
Suggested by: Shawn Brennan (25 Oct, '22) Upvoted: 20 Dec, '22 Comments: 0
Needs more information or votes Enhancement Feature Enhancement

Work in Revit While having GUI's open.

Can we make it so that when we are manipulating the conduit run schedule or any of the GUI's that you can still work in revit and be able to do R&D with it.
Suggested by: Anonymous (03 Sep, '21) Upvoted: 22 Feb, '23 Comments: 0
Needs more information or votes Feature Enhancement

Add the 3 d submittal text to the plan view for equipment and light fixtures.

It is nice that you have the Check box or X that shows in 3d whther or not the submittal is approved but it would be even better if it showed in plan view so that ...
Suggested by: Anonymous (16 Oct, '20) Upvoted: 12 Dec, '23 Comments: 0
Needs more information or votes Content Feature Enhancement

Incorporate connector option into bend family, this should work like the coupling feature.

it would save time when stubbing down to panels or into boxes with conduit bends to have the option of selecting to have a connector or a coupling on either end of ...
Suggested by: Mark Sprong (26 May, '20) Upvoted: 27 Jun, '23 Comments: 0
Planned (Added to Roadmap) Feature Enhancement

Add B22B configuration to strut family

add B22B config to strut family
Suggested by: Adam Heon (18 Oct, '19) Upvoted: 06 Dec, '22 Comments: 0
Needs more information or votes Content Feature Enhancement

Import Conduit Run Schedule Function to come from Excel or Google Sheets

Our company uses Google Sheets for our Conduit Schedules. So it would save us a lot of steps to have this function.
Suggested by: Anonymous (04 Jun, '21) Upvoted: 26 Oct, '21 Comments: 0
Needs more information or votes Feature Enhancement

Modify Spool Window rfa to allow multiple views of the same type

By modifying the spool window family it is possible to create multiple views of the same type on a single spool i.e multiple "Elevation Top" views. This is necessary ...
Suggested by: Jason (12 May, '21) Upvoted: 26 Oct, '21 Comments: 0
Needs more information or votes Feature Enhancement

Kicked 90s. Make reversed fixed end and reverse direction one button since they are dependent on ea

Removes the need to remember to check both and will not brake conduit fitting
Suggested by: Mike King (31 Aug, '20) Upvoted: 26 Oct, '21 Comments: 0
Needs more information or votes Feature Enhancement

Hanger collision detection

Is it possible to have trapeze collision detection monitor loaded coordination models (NWCs,NWDs etc) instead of/as well as revit models.
Suggested by: Josh Schmidt (28 Dec, '23) Upvoted: 28 Dec, '23 Comments: 0
Needs more information or votes Feature Enhancement Hangers

Exapnd "Element Filter Hot Keys" feature to include non-alphanumeric characters

Improvements in ui/ux would greatly benefit this tool. There is no clear documentation on how to activate the hot key function. The function also seems to activate ...
Suggested by: Jason (31 Dec, '20) Upvoted: 26 Oct, '21 Comments: 0
Needs more information or votes Feature Enhancement

Connect conduits on conduit runs of varying sizes

I would be nice if we have the ability to connect the conduit runs (comprising of 5+ conduits of varying sizes and elevations), based on the property of a chosen ...
Suggested by: Anonymous (28 Sep, '20) Upvoted: 26 Oct, '21 Comments: 0
Needs more information or votes Feature Enhancement

extend bolt lengths to 6"

extend bolt length options to 6" length
Suggested by: Anonymous (07 Nov, '19) Upvoted: 26 Oct, '21 Comments: 0